TEMPERATURE INDICATORS

 

DIGITAL TEMPERATURE INDICATORS

Model : ADI-111, ADI-211, ADI-311H, ADI-311V, ADI-111Zone
Display : RED 3œ Digit, 0.56" height
Range : 0șC to 50.0șC, 199.9șC, 400șC, 600șC, 1200șC, 1600șC

        SPECIFICATIONS :-

Input sensor calibration : .
a. Thermocouple : Iron-constant (Fe-Con)-up to 400șC
: Chromael-Alumel (Cr/Al)-up to 1200șC
Platinum-Platinum-Rhodium (Pt/Pt-Rh)-up to 1600șC
b. RTD :

Resistance Temperature Detector (Pt-100) temperature & upto 400șC

Indication Accuracy : ±1% of FSD
Compensation :

Cold junction compensation automatic thermocouple models

Relay Status : Relay energized or heating ( or cooling)
Relay output : One chance over relay contact 5A/230V rating.
Control Action : ON-OFF or time proportional
Control Version : single set point or Dual set point
Sensor break protection : Relay turns off in case of sensor break
Power Supply : 230V AC±15%, 50 Hz
Indication : Mains ON, Relay ON and thermocouple
Max, ambient temp. : 55șC
INSTALLATION :

The RTD sensor should be connected to instrument by proper cables to minimum due to cable resistance. For Thermocouple sensor, compensating cable of proper be used.  


Model Series 100 200 300H 300V
Size (mm) 96 x 96 72 x 72 48 x 96 96 x 48
Cutout (mm) 92 x 92 68 x 68 44 x 92 92 x 44
Depth (mm) 100 12075 for indicators  120 120
Mounting 100 12075 for indicators 120 120
Mounting

Flush panel mounting with side clamps fixed panel

Specifications are subject to change due to continuous des improvement

ORDERING INFORMATION

:

For better selection or model, range and calibration

Model No. : Specify possible better as
Type of sensor : Pt-100, Cr/Al or 13%
         

<< Back | Next >>

Copyright©2006, All Right Reserved, Alfa Instruments